CPCI Power Supply

PD15: CP3-SVE-M100DC

RID 24139 PD15, Rev.02

Regulation

Protection and Control

Initial Set Accuracy

< 1.0 % (no load)

Short circuit

Continuous short circuit proof

Ripple & Noise

Output 1 and 2: < 50 mV pk-pk, 20 MHz

bandwidth

Output 3: < 240 mV pk-pk, 20 MHz

bandwidth

Max. Output Capacitance

500 uF x Iout nom

Temperature Coefficient

< 0.02 %/°C

Line regulation

< 0.3% for 5V and 3.3V

Load regulation

1.0 % at Iout 0 - 100%

Response time

< 1ms at 25..75%

Overvoltage protection

115% to 130% Vout

Automatic repetition

Overcurrent protection

Output 1:

At overload and short circuit the converter
switches off the output and tries to restart
after 2 sec.

Output 2:

At overload and short circuit the converter
switches off the output and tries to restart
after 2 sec.

Output 3:

At overload and short circuit the converter
switches off the output and tries to restart
after 2 sec.

Current limitation

14 .. 17A for 3.3V
12 .. 15A for 5V
10.5 .. 12 for 12V

Effective for all outputs, outputs short-circuit
proof