PD15: CP3-SVE-M100DC
CPCI Power Supply
RID 24139 PD15, Rev.02
2.4
Electrical Specifications
Overview
Input
Output
INPUT
Input Voltage Nominal
24V DC
36V DC
48V DC
72V DC
110V DC
Under Voltage Turn-on
<16,8V DC
Under Voltage Turn-off
<14,4V DC
(14,4V < Vin < 16,8V at t > 1 sec.)
Input Current @ Full Load
5.29A
3.43A
2.54A
1.67A
1.08A
OUTPUT
Output 1
Output 2
Output 3
Output Voltage Nominal
3.3V DC
5V DC
12V DC
Output Current Nominal
12A
(14A for 20 ms)
10A
(12A for 20 ms)
4.8A
(10.5A for 20 ms)
Input voltage ranges
14.4V..154V DC ( t
≤
0.1 sec; EN50155 )
16.8..137.5V DC (constant)
Efficiency
Typ. 85%
Input current limitation
Yes
Fuse
10AT (not user serviceable)
Enable / Inhibit Signal
EN connected to Vin+: ON
EN open or connected to Vin-: OFF
Active Reverse Polarity Protection
Max.160 V
Inrush Current Limitation
Max. 20 A
Hold-up-time
> 10 ms at full load
False Signal
Open-collector output, active low
Output Voltage
3.3 V / 5 V / 12 V
Temperature coefficient
No derating over the specified temperature
range
Switch on / switch off performance
No overshooting (soft-start)
Rise-delay time
< 100ms
Start-up time
≤
20ms
Minimum load