1 node auto shutdown sensor – next steps, 4 power supply, 1 power supply status sensors – Kontron S4600 SEL Troubleshooting User Manual

Page 48: Power supply, Power supply status sensors, Node auto shutdown sensor, Next steps

Advertising
background image

Power Subsystems

System Event Log Troubleshooting Guide for EPSD

Platforms Based on Intel

®

Xeon

®

Processor E5 4600/2600/2400/1600/1400 Product Families

38

Intel order number G90620-002

Revision 1.1

Byte

Field

Description

[6:0] Event Type = 03h (

“digital” discrete)

14

Event Data 1

[7:6]

– 00b = Unspecified Event Data 2

[5:4]

– 00b = Unspecified Event Data 3

[3:0]

– Event Trigger Offset

1h = State Asserted

15

Event Data 2

Not used

16

Event Data 3

Not used

4.3.3.1

Node Auto Shutdown Sensor – Next Steps

This event is accompanied by specific power supply errors (AC lost, PSU failure, and so on) or other system events. Troubleshoot
these events accordingly.

4.4 Power Supply

The BMC monitors the power supply subsystem.

4.4.1

Power Supply Status Sensors

These sensors report the status of the power supplies in the system. When a system first AC applied or removed, it can log an event.
Also if there is a failure, predictive failure, or a configuration error, it can log an event.

Table 20: Power Supply Status Sensors Typical Characteristics

Byte

Field

Description

11

Sensor Type

08h = Power Supply

12

Sensor Number

50h = Power Supply 1 Status

51h = Power Supply 2 Status

13

Event Direction and
Event Type

[7] Event direction

0b = Assertion Event

1b = Deassertion Event

Advertising
This manual is related to the following products: