Cooling Subsystem

Revision 1.1

Intel order number G90620-002

45

5. Cooling Subsystem

5.1 Fan Sensors

There are three types of fan sensors that can be present on Intel

®

Server Systems: speed, presence, and redundancy. The last two

are only present in the systems with hot-swap redundant fans.

5.1.1

Fan Tachometer Sensors

Fan tachometer sensors monitor the rpm signal on the relevant fan headers on the platform. Fan speed sensors are threshold-based
sensors. Usually they only have lower (critical) thresholds set, so that a SEL entry is only generated if the fan spins too slowly.

Table 29: Fan Tachometer Sensors Typical Characteristics

Byte

Field

Description

11

Sensor Type

04h = Fan

12

Sensor Number

30h-3Fh (Chassis specific)

BAh-BFh (Chassis specific)

13

Event Direction and
Event Type

[7] Event direction

0b = Assertion Event

1b = Deassertion Event

[6:0] Event Type = 01h (Threshold)

14

Event Data 1

[7:6]

– 01b = Trigger reading in Event Data 2

[5:4]

– 01b = Trigger threshold in Event Data 3

[3:0]

– Event Trigger Offset as described in Table 30

15

Event Data 2

Reading that triggered event

16

Event Data 3

Threshold value that triggered event

The following table describes the severity of each of the event triggers for both assertion and deassertion.