25_anchorage,perimeter_seal – Oldcastle BuildingEnvelope 6000 Series Thermal MultiPlane User Manual

Page 26

Advertising
background image

25






S E R I E S 6 0 0 0 T H E R M A L M U L T I P L A N E I N S T A L L A T I O N M A N U A L

OUTSIDE GLAZED

ANCHORAGE & PERIMETER SEAL

Optional MO-1188/MO-244

Head receptor

Maximum end reaction is 450 lbs

FG-6430-01 head anchor

for center set system only

Maximum end reaction is 600 lbs

Apply sealant along length of sill flashing at point (A).

Once the frame is secured, apply a fillet seal between the

sill flashing and the front of the sill member (B).

The quality of the inside and outside perimeter seals (C)

may be improved by using FG-6188 PVC filler. The part

may be used in full lengths or cut into pieces to provide

support for the backer rod regardless of joint size. Interior

perimeter seal at the sill (D) is optional and for cosmetic

purposes only.

NOTE:

1/4" weep holes

required in flashing (E)

at centerline of D.L.O.

FG-6188

optional PVC filler

for sealant backer

FG-6188

optional PVC filler

for sealant backer

Optional FG-6188 PVC

filler runs between head anchor

C

C

C

C

C

C

B

E

A

A

D

B

E

A

A

D