Digital

Indicator

Digital

Transmitter

Dual Port

Leveling

Valve

Dual Port

Air Transducer

Driver

Side

Passenger

Side

Tee

Fitting

Applications

13

Figure 4-4. Block Diagram

Note

If tractor air suspension, connect to indicator channel 1 terminals. If trailer air suspension, connect to indicator
channel 2 terminals.

3. Mount the transducer using the two 9/32" (7 mm) diameter mounting holes in the case. Use ¼" bolts (2)

with flat washers (2) and nylock nuts or locking flange nuts (2). The installer may drill this size hole in the
chassis or a cross-member and use a through-bolt and lock nut to mount the transducer, or the transducer
may be mounted to a separate plate (min ¼" thick) which picks up existing chassis bolt holes. Do not
excessively over tighten any of the mounting bolts. Select a mounting location that is protected from road
hazards, petrochemicals and moving machinery, and is still accessible for inspection and testing. See
Figure 4-5.