Underside Trailer Mount

4.50
Min

Ø 4.00

Trunnion

Tube

4X Torque Bolt

to 380 ft/lbs

6X Torque Bolt

to 190 ft/lbs

Anti-rotation Plate

Anti-rotation Plate

2.62

4.5 x 17.5 x .75
1018 CRS

Bend tabs up on hex flat
after final assembly.

3/16

Important

Applications

47

Do not weld the bearing plates while they are attached to the load cells as this may result in damage to
the load cell from overheating or arcing on the load cell. Improper grounding of weld current may also
destroy load cells, so they must be completely removed for final welding. See “Welding Specifications” on
page 59.

Figure 4-46. Final Assembly

Table 4-4. Specifications

Bolt Size

1-1/8" -12 UNF x 3.25"L Bolt

1000 to 1200 lb/ft. (1355-1626 Nm)

Clamp Bolts and Locknuts

380 to 420 lb/ft (542 to 600 Nm)

CONNECTIONS

1. Connect the trailer transmitter leads (2) to the load cell connectors.

Note

The transmitter has a RED lead (with red heat shrink tubing) and a BLACK lead (no heat shrink, which identifies
the load cell for diagnostics testing in the meter program).

2. Mount the transmitter in a protected area of the trailer under structure.