EXAMPLE: OB30L-F3 System
Balancing Weights:

English = 5000 lb.

Metric = 2000 KG

Graduations:

English = 5 lb.

Metric = 2 KG

First Loading

English Units (lbs.)

Cell

Metric Units (kg)

M2000 Reading

M2000 Reading

Start Loaded

Unloaded

Start Loaded

Unloaded

0

4995

0

1

0

1998

0

0

4990

0

2

0

1996

0

0

5005

0

3

0

2002

0

From the above results, it can be seen that cells 1 and 3 must be adjusted down

to read 4990 lbs. (1996 kg in the metric example). First, the trimmer for cell 1
is turned clockwise to bring the reading down (step 6(c)).
Second Loading

English Units (lbs.)

Cell

Metric Units (kg)

M2000 Reading

M2000 Reading

Start Loaded

Unloaded

Start Loaded

Unloaded

0

4990

0

1

0

1996

0

2

3

Next, the trimmer for cell 3 is turned clockwise to bring its reading down.
Because this cell is being adjusted by three graduations, the procedure in 6(d)

should be followed, adjust cell 3 down to 4985 lbs. (1994 kg in the metric
example) and check for a zero shift.
Third Loading

English Units (lbs.)

Cell

Metric Units (kg)

M2000 Reading

M2000 Reading

Start Loaded

Unloaded

Start Loaded

Unloaded

1

2

0

4985

-5

3

0

1994

-2

The unloaded reading is found to be –5 lb (-2 kg), indicating a zero shift. The
scale must therefore be re-zeroed, and cell 3 checked again.
Fourth Loading

English Units (lbs.)

Cell

Metric Units (kg)

M2000 Reading

M2000 Reading

Start Loaded

Unloaded

Start Loaded

Unloaded

0

4990

0

1

0

1996

0

0

4990

0

2

0

1996

0

0

4990

0

3

0

1996

0

THE CELLS ARE NOW BALANCED WITHIN THE TOLERANCE OF ONE
GRADUATION.