Rice Lake TradeRoute HL Series - M2000 Scale User Manual

Page 41

Advertising
background image

37

0: No parity
1: ODD parity

2: Even parity.
33 Parity for COM 2 (0)
34 Stringmode for COM1 (99)

The M2000 supports several string output modes through either COM1 or
COM2. Select the string mode from the table below. Use 99 if you are using

the COM port for ticket printing.
1 DF1000
3 DF2000

5 DF2500 mode1
8 DF1500
9 DF2500 mode 6

10 DF2500 mode 7
12 AD4321, AD4323, AD5000
13 Cardinal 708

14 Cardinal 738
19 Toledo & Fairbanks R2500
16 Weightronix 120

17 Consolodated Controls
18 Analogic 5316

99 Set to ticket printer mode
35 Stringmode for COM2 (8)
36 Flow Control for COM1 (0)

Select 0 for none and 1 for Hardware
37 Flow Control for COM2 (0)
38 String output polled mode for COM1 (5)

39 String output polled mode for COM2 (5)
0

selected output string will be continuously transmitted on COM1

1

selected output string will be transmitted on COM1 when the

PRINT/SELECT key is pressed

2

output when the receive data input is at logic low (-9 volts dc). A

string will be transmitted after each sample whenever the receiver
data line is held low – send on break. output when the receive data
input is at logic high(+9 volts dc). A string will be transmitted after

each sample whenever the receiver data line is held high – send on idle

4

output string to COM1 on ‘?’ character received

5

output string to COM1 continuously

47 Serial String Output Routing FOR COM1 (0)
48 Serial String Output Routing FOR COM2 (0)
Parameter 47 and 48 will determine which channel’s weight will be routed the

COM serial port. This parameter will only be implemented if the calibration
values meet the criteria.



0 COM1 serial output string weight a function of current active channel



1 COM1 serial output string locked on channel 1

Advertising