Troubleshooting - procedure b – Thetford NR740 User Manual

Page 4

Advertising
background image

DC0040(K), DC0051(K), DE0040, DE0051, DE0240T, DE0251T,

DC0740(X), DE0740(X), DC0751(X), DE0751(X) Models

Refrigerator Service Manual

4

Troubleshooting - Procedure B

Compressor Resistance

Measure

Compressor

Resistance.

See Figure 3.

0

 

1.4 – 3.5 

Normal

Internal

Compressor

Failure

See

Procedure C

Change

Cooling Unit

Note: Perform procedure at room temperature.

AR

T0

19

47

Measuring the Compressor Resistance

Turn the temperature control to the "Off" position.

1.

Remove the black wire to the compressor.

2.

Measure the resistance of the compressor between point

3.

A and point B. Refer to Figure 3.

Figure 3. Measuring Compressor Resistance

AR

T01958

B A

Compressor Resistance

Advertising