HS115-3, 4, 5 SERIES CONNECTED TO ANY 115V BURNER MOTOR OR GAS VALVE

(BURNER MOTOR OR GAS VALVE LESS THAN 3 AMPS @ 120 VAC)

MAC-4 CONTROL WIRED WITH UP TO FOUR 24V GAS APPLIANCES AND ONE TJERNLUND

HS115-3,4,5 POWER VENTER (MOTOR LOAD UP TO 1 H.P.)

TJERNLUND PRODUCTS, INC.

1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com

MODEL HS115-3, HS115-4 & HS115-5 WIRING DIAGRAM ADDENDUM

WARNING:
The BLACK & WHITE Power Venter motor wires shown the diagram below are applicable only for the HS115-3. For models
HS115-4 & HS115-5 use BLACK and WHITE wires from electrical box wip and connect to proper terminals on motor. See motor
nameplate for proper wiring.

Upon first startup, as viewed from opposite end of shaft, verify HS115-4 & HS115-5 motors

rotate clockwise. Mount electrical box with Fan Prover in a vertical position. See instructions for proper installation of Fan
Prover Sensing tube. HS115-3,4,5 Motor and Fan Prover specifications are the same as the equivalent HS-3,4,5 model.