AUTO-DRAFT® VENTER FAN PERFORMANCE CURVES
Auto-Draft® Venter performance was independently tested by an accredited AMCA certified testing facility.
Selection of an Auto-Draft® Venter involves determination of the maximum volume of gas to be handled, the density of the gas and
the maximum static pressure which the fan must overcome.
Variable speed VSAD-Series Venters can operate at virtually any point to the left of the performance curve. For Side Wall applica-
tions add 0.50” W.C. to vent system resistance to accommodate the effects of wind loading.
Auto-Draft® Venter performance needs to be derated from 70
O
F performance curves to anticipated flue gas temperatures.
Please feel free to contact us for application and model selection assistance by calling 800-255-4208 or email us at
[email protected]. Vent layout or other information can be faxed to 651-426-9547.
2
CFM (STD AIR 70 DEGREES F)
STATIC PRESSURE
IN. W.C.
VSAD−8
FSAD−8
CFM (STD AIR 70 DEGREES F)
STATIC PRESSURE IN. W.C.
VSAD−12
FSAD−12
CFM (STD AIR 70 DEGREES F)
STATIC PRESSURE IN. W.C.
VSAD−10
FSAD−10