VRM Cooling System Typical Installation
• Keep line sets as short as possible.
• Excessive number of turns will
cause refrigerant flow problems. 
This could cause early compressor 
failure. Suction line accumulators are 
recommended. Required if working 
lower than the normal 55-65° 
operating range from wine cellar
• Drain line must always flow downhill
to drain or pump
• The system is controlled by a pump
down control system. There is no 
control wiring between thermostat 
and condensing unit
• The line connections at Fan Coil and
Condensing Unit may not be the 
same as the required line sizes
• Standard line sets should be 50’
or less. Extended runs may require 
larger line sizes and 3oz. oil must be 
added for every 10’ over 35’