ROUTING OF PIPING
The refrigerant piping can be routed to the unit in
a number of ways (left or tight from the back of
the unit) by using the cut-out holes on the casing
of the unit (see figure). Bend the pipes carefully to
the required position in order to be aligned with
the holes. For right hand and rear side drawing
out, hold the bottom of the piping and then fix the
direction (see figure). The condensation drain hose
should be taped to the pipes.
WATER DRAINAGE PIPING
The indoor drain pipe must be downwards
gradient for smooth drainage Avoid situations that
are likely to cause water leaking.
Check to see that there is a good flow of
condensate water into the drain pan.
MOUNT THE UNIT ONTO THE
INSTALLATION PLATE
Hook the indoor unit onto the upper portion of
the installation plate (engage the two hooks at
the rear top of the indoor unit with the upper
edge of the installation plate) To ensure that the
hooks are properly seated on the installation
plate, try checking by moving it slightly to left
and to the right.
1. Hook the unit onto the installation plate.
2. A unit support plate
on the installation plate
can be used to hold the
unit slanted (see figure)
to ease the piping
installation work
3. Fix the screw
underneath after
completion of installation
HORIZONTAL AIR FLOW CONTROL
For more effective air circulation, you can
manually adjust the air discharge grille to the left
or right.