Troubleshooting – Vinten Radamec Virtual Reality interface (VRi) User Manual

Page 18

Advertising
background image

16

Troubleshooting

Fault

Check

Comments

VRi box is switched on, but
mains, 5V and 12V power
indicator LEDs are not
illuminated.

Check that either a 50–60 Hz AC mains power supply of 100–
240V or a DC power supply of 9.5–28V is connected.

If DC output from the VRi box is in use, try disconnecting it in
case the load is too high

If a mains supply is connected to the VRi box, check and/or
replace the fuse.

Genlock indicator LED is red.

Check that the genlock signal from the studio supply is con-
nected to the Genlock In BNC connector.

If using a camera as a genlock source, the output must be
configured to genlock black.

If the problem persists, contact Vinten or
Vinten Radamec customer support.