1−24 — The number of months after which the Humidifier Pad Reminder icon

will be displayed, “CHECK HUM PAD”.
Default is OF (off).
Option 30 — Programmable Fan (programmable models only)
This selection allows the homeowner to program the fan selection to “Auto” or

“On” fan operation for each of the program schedule periods. This selection is

only available on programmable Thermidistat Controls.
OF (off) — Programmable fan is disabled and the homeowner must manually

select “Auto” or “On” for fan operation.
On — Programmable fan is enabled. The homeowner can program “Auto” or

“On” fan operation along with the heat and cool setpoints for each programmed

period. When the program schedule is running, the programmed heat setpoint,

cool setpoint, and fan selection for that period will be used. If the homeowner

“overrides” the programmed fan setting by pressing the fan button, the override

selection will remain in effect until the next programmed period time.
Default is OF (off).
Option 31 — Daylight Savings Time Configuration (programmable models
only)
This selection allows the installer to set the Thermidistat Control to automatically

change by one hour on the specified day, month, and week specified.
OF (off) — Daylight Savings Time Function disabled.
1,2 On — The first time the UP/DOWN button is pressed, the value of this

selection changes from OF (off) to 1. When 1 is displayed, the days of the week

and clock digits will be turned on. The installer will set the start date (Spring) for

Daylight Savings Time by setting the day of the week by selecting the

appropriate triangle icon next to the days of the week, the month of the year will

Advertising