Zippy RPU-6400F-RV2S User Manual

Page 19

Advertising
background image

INPUT CHARACTERISTICS:

RPX - 4400 / 5400

* VOLTAGE : 95 - 132 VAC OR 190 - 264 VAC SWITCHABLE
* FREQUENCY : 47 - 63 HZ
* INPUT CURRENT : 4.0 A / 2.0 A PER UNIT (PARALLEL)

8.0 A / 4.0 A ( ONE POWER SUPPLY )

* INRUSH CURRENT : 40 A MAX. FOR 115 VAC,

80 A MAX. FOR 230 VAC ( ONE POWER SUPPLY)

OUTPUT CHARACTERISTICS :


OUTPUT

CURRENT

REGULATION

OUTPUT

MIN. (A)

MAX. (A)

LOAD

LINE

7.0

36/72*

3.0**

20/40**

12

2.5

24/48*

+ / - 3%

+ / - 1%

100 mV

-5V

0

1

+ / - 10%

+ / - 1%

150 mV

-12

0

1

+ / - 10%

+ / - 1%

150 mV

3.3***

3

20

+ / - 3%

+ / - 1%

50 mV

OUTPUT

VOLTAGE

RIPPLE & NOISE

MAX. (P-P)

5

50 mV

+ / - 3%

+ / - 1%


* : PEAK FOR 1 MINUTE

** : UNDER WITH 3.3 V OUTPUT CONDITION

*** : 3.3 OUTPUT IS OPTIONAL

ACTUAL POWER USAGE SHALL NOT OVER THE TOTAL OUTPUT POWER


THE MAX. TOTAL OUTPUT OF +5V AND +3.3V IS 160W.


* TEMPERATURE RANGE : OPERATING 0

°

C --- 50

°

C, STORAGE -20

°

C --- 80

°

C

* TRANSIENT RESPONSE : OUTPUT VOLTAGE RETURNS IN LESS THAN 1 ms

MAX. FOLLOWING A 50 % LOAD CHANGE

* HOLD UP TIME : 16 ms MINIMUM AT FULL LOAD & NOMINAL INPUT VOLTAGE
* DIELECTRIC WITHSTAND : INPUT TO FRAME GROUND 1500 VAC FOR 1 SEC.
* HUMIDITY : 10 - 90 % RH
* EFFICIENCY : 70 % TYPICAL AT FULL LOAD
* POWER GOOD SIGNAL : ON DELAY 100 ms TO 500 ms, POWER FAIL

≥ 1 ms

* OVERLOAD PROTECTION : 110 - 150 % MAX. ( POWER UNIT )
* OVER VOLTAGE PROTECTION : + 5V OUTPUT: 5.5 V --- 6.5 V

+ 12V OUTPUT: 13.5 V --- 15.5 V ( OPTIONAL )

* SHORT PROTECTION
* ALARM METHOD: 1) AUDIO ALARM 2) FAULT LED 3) POWER DEFECTIVE SIGNAL
* EMI NOISE FILTER: AC INPUT LINE FILTER FOR FCC CLASS B ON EACH UNIT
* SAFETY: EACH POWER UNIT ARE UL / CSA / TÜV APPROVAL
* HOT-SWAPPABLE & HOT-PLUGGABLE CAPABILITY
* DIMENSION : REFER THE DRAWING
* REDUNDANCY: BALANCED SHARE LOAD METHOD