Output characteristics, Specification – Zippy RPU-6400F-RV2S User Manual

Page 20

Advertising
background image

INPUT

CHARACTERISTICS:

RPX-5300F

/

5400F-RV

VOLTAGE: 90 - 132 VAC / 180 - 260 VAC SWITCHABLE

FREQUENCY: 47 - 63 Hz

INPUT CURRENT: 3.0A / 1.5A PER UNIT (PARALLEL), 6.0A / 3.0A (ONE POWER)

INRUSH CURRENT: 40A MAX. FOR 110 VAC, 80A MAX. FOR 220VAC

OUTPUT CHARACTERISTICS:

OUTPUT CURRENT

REGULATION

OUTPUT

MIN. [A]

MAX. [A]

LOAD

LINE

+5V

7.0

30/50*

±

5%

±

1%

50mV

-5V

0

0.5/1.0*

-10%~+14%

±

1%

150mV

+12V

2.5

11

±

6%

±

1%

100mV

-12V

0

0.5/1.0*

-10%~+15%

±

1%

150mV

+3.3V

1.0

25/18*

±

5%

±

1%

50mV

+5VSB

0

800mA

±

5%

±

1%

50mV

RIPPLE & NOISE

MAX. [P-P]

OUTPUT

VOLTAGE

*

N / N: 300 / 400W
300W VERSION: +5V AND +3.3V TOTAL OUTPUT MAX: 150W
400W VERSION: +5V AND +3.3V TOTAL OUTPUT MAX: 250W

SPECIFICATION:

TEMPERATURE RANGE: OPERATING 0

-- 50

; STORAGE -20

-- 80

TRANSIENT RESPONSE: OUTPUT VOLTAGE RETURNS IN LESS THAN 1 ms MAX.

FOLLOWING A 50% LOAD CHANGE

HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE

DIELECTRIC WITHSTAND: INPUT / OUTPUT 1500 VAC FOR 1 SECOND

INPUT TO FRAME GROUND 1500 VAC FOR 1 SECOND

HUMIDITY: 10 ~ 90% RH

EFFICIENCY: 60% TYPICAL, AT FULL LOAD

POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms

OVER LOAD PROTECTION: 130 ~ 150% MAX.

OVER VOLTAGE PROTECTION: +5V

5.5V ~ 7.0V, 3.3V: 3.8V ~ 4.5V

OVER CURRENT PROTECTION: SHORT CIRCUIT

ALARM METHOD: 1. AUDIO ALARM, 2. FAULT LED, 3. POWER DEFECTIVE SIGNAL

EMI NOISE FILTER: AC INPUT LINE FILTER FOR FCC CLASS B ON EACH POWRE
UNIT ARE AVAILABLE UPON ORDER

SAFETY: UL / CSA / TÜV APPROVAL

HOT-SWAPPABLE / HOT-PLUGGABLE CAPABILITY

DIMENSION: REFER TO THE DRAWING

REDUNDANCY: BALANCE SHARE LOAD METHOD

REMOTE ON/OFF: OPERATE BY A REMOTE (SELV) SIGNAL

5VSB STANDBY VOLTAGE: A LOW CURRENT CONTINUOUS 100mA SOURCE
AT +5V, ALWAYS ENABLE, CAN NOT BE SWITCHED OFF

21