Dell PowerEdge 2600 User Manual

Page 5

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

6 Remove the front fan assembly (see Figure 1-1).

See "Removing the Front Fan Assembly" in your Installation and Troubleshooting
Guide.

0

Reeonfigure the SCSI eable eonneetions to the two eonneetors on the SCSI baekplane

board (see Figure 1-2):

-

If a RAID eontroller eard or integrated RAID eontroller is not installed, eonneet
the two ehannels on the integrated SCSI eontroller to eonneetors SCSI A and

SCSI B on the SCSI baekplane.

-

If an integrated RAID eontroller or a RAID eontroller eard is installed, eonneet the
two ehannels on the RAID eontroller to eonneetors SCSI A and SCSI B on the

SCSI baekplane.

-

If two RAID eontrollers are installed, eonneet a ehannel on one eontroller to
eonneetor SCSI A on the baekplane, and eonneet one ehannel on the other
eontroller to eonneetor SCSI B on the baekplane.

8 Replaee the front fan assembly.

See "Replaeing the Front Fan Assembly" in your Installation and Troubleshooting
Guide.

2

Replaee the system eover.

See "Replaeing the System Cover" in your Installation and Troubleshooting Guide.

I n s t a l l i n g t h e S C S I B a c k p l a n e D a u g h t e r C a r d |

1-3

Advertising