¾ Menu Descriptions & Functions [Factory default]

Returning to Factory Default [Factory default]

The Factory default feature allows you to change adjustments and settings to the factory presets.

[Current signal]

Resets the adjustments for the current signal to the factory preset levels.
The items that can be reset are: Brightness, Contrast, Color, Color balance, Sharpness, Noise reduction, Aspect,
Horizontal position, Vertical position, Clock, Tracking and Image mode.

[All data]

Resets all the adjustments and settings for all the signals to the factory preset for source except the following:
Language, Password, Communication speed, Remaining lamp time, Lamp counter, Filter usage and Projector
usage. To reset the lamp and filter usage time, see “Lamp counter” and “Clear filter usage”.

Resetting the Filter Usage Hours [Clear filter usage]

Resets the filter usage back to zero. Selecting this option displays submenu for a confirmation. Select “Yes” and press
the OK button.

NOTE: Reset the Filter usage after cleaning or replacing the filter.

Clearing Lamp counter [Lamp counter]

Resets the lamp clock back to zero. Selecting this option displays a submenu for a confirmation. Select “Yes” and press
the OK button.

NOTE: Do not reset the lamp counter except when you have replaced the lamp. If reset, the lamp counter cannot indicate the
correct timing of lamp replacement.
For the lamp replacement method, see page

49

.

NOTE: The projector will turn off and go into standby mode after 2100* hours (up to 3100* hours in Quiet mode) of service.
If this happens, press the INFO. button on the remote control for ten seconds to reset the lamp clock back to zero.
When the lamp time clock is reset to zero, the LAMP REPLACE indicator goes out.
Do this only after replacing the lamp.
* LV-X5: 3100 hours (up to 4100 hours in Quiet mode).