Pilz PNOZ s10 C 24VDC 4 n/o 1 n/c User Manual

Page 9

Advertising
background image

PNOZ s10

Operating Manual PNOZ s10
21402-EN-08

9

Relay outputs

750110

751110

Utilisation category

In accordance with the standard

EN 60947-5-1

EN 60947-5-1

Auxiliary contacts, AC15 at

230 V

230 V

Max. current

2,0 A

2,0 A

Auxiliary contacts, DC13 (6 cy-

cles/min) at

24 V

24 V

Max. current

2,0 A

2,0 A

Safety contacts, AC15 at

230 V

230 V

Max. current

6,0 A

6,0 A

Safety contacts, DC13 (6 cycles/

min) at

24 V

24 V

Max. current

7,5 A

7,5 A

Contact fuse protection, external

safety contacts

In accordance with the standard

EN 60947-5-1

EN 60947-5-1

Blow-out fuse, quick

16 A

16 A

Blow-out fuse, slow

10 A

10 A

Circuit breaker, 24V AC/DC,

characteristic B/C

10 A

10 A

Contact fuse protection, external

auxiliary contacts

Blow-out fuse, quick

4 A

4 A

Blow-out fuse, slow

2 A

2 A

Circuit breaker, 24 V AC/DC,

characteristic B/C

2 A

2 A

Contact material

AgSnO2 + 0,2 µm Au

AgSnO2 + 0,2 µm Au

Conventional thermal current

while loading several contacts

750110

751110

Ith per contact at UB DC

Conv. therm. current with 1 con-

tact

12,00 A

12,00 A

Conv. therm. current with 2 con-

tacts

11,00 A

11,00 A

Conv. therm. current with 3 con-

tacts

9,00 A

9,00 A

Conv. therm. current with 4 con-

tacts

8,00 A

8,00 A

Times

750110

751110

Switch-on delay

With automatic reset after power

on typ.

30 ms

30 ms

With automatic reset after power

on max.

50 ms

50 ms

Delay-on de-energisation

With E-STOP typ.

20 ms

20 ms

With E-STOP max.

30 ms

30 ms

With power failure typ.

20 ms

20 ms

With power failure max.

30 ms

30 ms