Maintenance – Ryobi RYI1000 User Manual

Page 21

Advertising
background image

17 — English

MAINTENANCE

STORAGE

When preparing the generator for storage, allow the unit to cool for 30 minutes then follow the guidelines below.

STORAGE TIME

PRIOR TO STORING

Less than 2 months  Drain gasoline from tank and dispose of in a suitable container according to state and local

ordinances.

2 months to 1 year

Drain fuel from carburetor.

Drain gasoline from tank and dispose of in a suitable container according to state and local
ordinances.

1 year or more

Drain fuel from the carburetor.

 Remove spark plug.

Drain gasoline from tank and dispose of in a suitable container according to state and local
ordinances.

Put a tablespoon of engine lubricant into the spark plug cylinder. Turn the engine slowly with the
pull rope to distribute the lubricant.

 Reinstall spark plug.

Change engine lubricant.

After removal from storage:

Fill with fresh gasoline.

NOTE: If storing gasoline in suitable container for later use, make sure gasoline has been treated with fuel sta-
bilizer according to stabilizer manufacturer’s instructions.

MAINTENANCE SCHEDULE

NOTE: If a separate engine manual is provided for this generator, please follow the maintenance schedule provided in the
engine manual instead of the maintenance information listed below.

Before

each use

After 1st month

or 20 hours of

operation

Every 3 months

or 50 hours of

operation

Every 6 months

or 100 hours

of operation

Every year or

after 300 hours

of operation

Check Engine Lubricant

Change Engine Lubricant

Check Air Filter

Clean Air Filter

Change Air Filter

Check/Adjust Spark Plug

Replace Spark Plug

Clean Fuel Tank and Filter

1

Check Fuel Hose

Check All Hose
Connections

Inspect Fuel Tank Vapor
Vent (If Equipped)

Inspect Carbon Canister
(CARB Models Only)

1. These items should only be carried out by an authorized service center.
NOTE: Maintenance should be performed more frequently when generator is used in dusty areas.

When generator has exceeded the maximum figures specified in the table, maintenance should still be cycled
according to the intervals of time or hours stated herein.

Advertising