Frequency mode, Program mode, Program-secure mode – BendixKing CNI 5000 User Manual

Page 6

Advertising
background image

The Frequency Mode (Normal Operation).
Standard COMM
1a.
Select a new frequency in the “STBY”
window, using the frequency selection
knobs. The larger knob controls changes in
increments of 1MHz. The smaller knob con-
trols changes in increments of 50kHz when
pushed in, and 25kHz when pulled out.
Proceed to Step 2.

Optional COMM
1b.
Select a new frequency in the “STBY”
window, using the frequency selection
knobs. The larger knob controls changes in
increments of 1MHz. The smaller knob con-
trols changes in increments of 25kHz when
pushed in, and 8.33kHz when pulled out.
Proceed to Step 2.

NOTE: On both the standard and optional
COMM, the outside limits of the band, the
display will “wrap around” to the other end
of the band, going from 136MHz to 118MHz.
2. Press the transfer button to activate the
new frequency. The newly entered fre-
quency in the “STBY” window flip-flops with
the frequency in the “USE” window. This
new frequency is now available for use. An
optional remote-mounted frequency trans-
fer button may also be used to perform this
flip-flop” function.

Program Mode.

The Program Mode is used to program

frequencies for use in the Channel Mode.
1. Depress the channel (CHAN) button for
more than two seconds, until the channel
number (to the right of the standby frequen-
cy) begins flashing. The most recently
used active frequency will remain displayed
in the “USE” window.

2. Turning either frequency selection knob
will change the channel.

3. Once you’ve selected the desired chan-
nel number, you may program a new fre-
quency by pressing the transfer button.
This will cause the frequency in the “STBY”
window to flash. The tuning knobs are now
used to enter desired frequency.

4. To program additional channels, push
the transfer button again to make the chan-
nel number flash, and repeat steps two and
three above.
5. If you wish to program fewer than nine
channels while skipping certain channel
numbers, rotate the MHz frequency knob
left or right beyond 136MHz or 118MHz.
Dashes (- - -) will appear in the “STBY”
window, indicating that the channel will be
skipped when the system is operating in
the Channel Mode.

6. To exit the Program Mode, momentarily
press the channel button. The unit will also
automatically exit the Program Mode if no
programming occurs within approximately
20 seconds.

The Program-Secure Mode.

The Program-Secure Mode may be

used to lock a desired frequency to a spe-
cific channel number, prohibiting program
changes from the front of the unit. This can
be accomplished by an authorized
Bendix/King Service Center.

5

OFF

PULL
TEST

USE

STBY

COMM 1

T

CHAN

PULL

25K

CHAN

OFF

PULL
TEST

USE

STBY

COMM 1

CHAN

PULL
8.33K

CHAN

OFF

PULL
TEST

USE

STBY

COMM 1

T

CHAN

PULL

25K

CHAN

OFF

PULL
TEST

USE

STBY

COMM 1

T

CHAN

PULL

25K

CHAN

OFF

PULL
TEST

USE

STBY

COMM 1

T

CHAN

PULL

25K

CHAN

OFF

PULL
TEST

USE

STBY

COMM 1

T

CHAN

PULL

25K

CHAN

OFF

PULL
TEST

USE

STBY

COMM 1

CHAN

PULL

25K

CHAN

Advertising