Table 4. system configuration report -6, Table 5. system configuration options -6 – CANOGA PERKINS 1502 Domain Management Module User Manual

Page 16

Advertising
background image

EdgeAccess Universal Chassis System

Table 4. System Configuration Report

Item Description

Chassis Type

Always 2U, the UCS 1002

Ethernet Address MAC address for the DMM

Ethernet Link

Shows link status (up or down) and current full or half-duplex

Current Bootcode Version number for bootcode for this module

Current Firmware Version number for firmware for this module

Active Bank

Flash memory that holds the currently-used firmware

Table 5. System Configuration Options

Menu Item

Description

1. System Contact
2. System Name
3. System Location

Optional information, up to 50 characters; also sets sys Name, sys
Location, and sys Contact information in Standard MIB

4. Default SNMPv1/v2c
Read Community

Password for SNMP Read access, up to 14 characters, default is
"public"

5. Default SNMPv1/v2c
Write Community

Password for SNMP Write access, up to 14 characters, default is
"private"

6. SLIP/PPP IP Address IP address for access through Serial Line Internet Protocol (SLIP) or

Point-to-Point Protocol (PPP)

7. DMM IP Address

IP address for this DMM; Table 6 lists the IP address classes and
default subnet masks

8. Subnet Mask

Mask that sets the network ID part of the IP address

9. Default Gateway

Address of the network node that connects to another network

10. BOOTP

"Enabled" if the module needs to obtain its IP address from a BOOTP
server; when the unit has an IP address, set to "Disabled"

11. Serial Port Mode

Type of serial port connection: VT100, SLIP, or PPP

12. Telnet Security

"Enabled" to use the security features included with Telnet;
"Disabled" to disable the Telnet security

13. Mgmt VLAN
Tagging

"Enabled" recognizes incoming management traffic only if it is
tagged to match item 14, Mgmt VLAN ID, ignores other traffic;
outgoing traffic will be tagged to match item 14
"Disabled" recognizes incoming management traffic only if it has no
VLAN tag, ignores all tagged traffic; outgoing traffic will not be
tagged

14. Mgmt VLAN ID

ID for the VLAN used for management

15. Mgmt VLAN P-Bit Priority for the VLAN used for management

Note: The SLIP or PPP IP address must be on a different network than the Ethernet IP address.

Because SLIP and PPP run point to point, the SLIP/PPP subnet mask is assumed from
the Class type of the SLIP/PPP IP address, and no gateway is allowed.