Manage a cim, Manage a cim -24 – CANOGA PERKINS 1502 Domain Management Module User Manual

Page 34

Advertising
background image

EdgeAccess Universal Chassis System

CHASSIS MANAGEMENT
Chassis:5 Bootcode Version Firmware Version
Slot LOCAL REMOTE L/ACT L/INA R/ACT R/INA
1 06.30 N/A 05.03 05.00
2 05.70 Offline 04.30 04.20
3 05.70 05.70 04.30 04.30 04.30 04.30
4 05.70 Offline 01.60 01.45
5 05.70 Offline 02.13 02.13
6 Empty
7 N/A N/A
8 N/A N/A
9 Empty
10 N/A N/A
11 Empty
12 05.50 Offline 01.60 01.60

Figure 8. Typical Chassis Management Screen, Firmware Information.

CHASSIS MANAGEMENT
Chassis:5 Available Chassis Power Remaining: 37.80 Watts
Slot Type Power Usage
1 1502 4.00 W
2 L311 4.00 W
3 L321 4.00 W
4 2346 4.00 W
5 L357 5.60 W
6 2346 4.00 W
7 L312 4.00 W
8 L322 4.00 W
9 2446 4.00 W
10 L342 4.00 W
11 Empty
12 L357 5.60 W

Figure 9. Typical Chassis Management Screen, Power Consumption Information.

Manage a CIM

The CIMs can interconnect up to eight chassis in one domain. Use the CIM Management screen
to view real time and static information about the chassis. Each CIM monitors a variety of
operational parameters for the chassis that it is in, including:

• Chassis type
• Power supply status and chassis temperature
• Clock status
• Major and Minor alarms status

3-24

Model 1502 Domain Management Module

Advertising