EdgeAccess Universal Chassis System

Use the Software Upgrade report and menu screen to check the current version of the DMM
firmware and to upgrade software for any module, except the CIM, in the domain or a managed
module partner, if necessary.

To access the Software Upgrade screen, follow these steps:

1. At the Domain Management Module menu, type

4

, Software Upgrade, and press <Enter>.

The Software Upgrade screen appears.

2. Record the Processor Version and the numbers for the Active and Inactive Firmware.

3. Contact your technical support person for assistance to determine if you need to update your

software and to receive the new file.

Caution:

To insure compatibility when a system includes two or more of the same module,
you must upgrade all those modules with the same software.

If the firmware for the DMM or other module is outdated, you need to upgrade it. The DMM
firmware file name is similar to

DMM0106.zip

, where "DMM" indicates the module and "0106"

indicates the version. To start the software upgrade, follow these steps:

1. Go to the Host Access Table (see page 3-15) and verify that the entry for the host you will

use for the file transfer allows FTP or SFTP access, depending on the method you plan to use.

2. Log in to the FTP or SFTP server from the account that allows access.

Note: You can run only one FTP or SFTP session at a time.

3. Download the new firmware to your TFTP server; put the firmware in the "

/BURNING

"

directory. For FTP, enable binary transfer mode. When the transfer is complete, the file is
moved automatically to the "

/INACTIVE

" directory if it is DMM firmware, or to the

"

/MODULES

" directory if it is firmware for another module.

4. Go to the System Configuration menu and enter the IP address, subnet Mask, and default

gateway for the DMM.

5. At the Domain Management Module menu, type

4

, Upgrade Software, and press <Enter>.

6. At the Software Upgrade menu, type

3

, Get New File with TFTP, and press <Enter>.

7. Follow the prompts on the screen to enter the IP address for the TFTP server and the file

name for the new firmware, then start the upgrade.

8. If this is new firmware for the DMM, when the file transfer is complete, go to the Software

Upgrade menu, type

2

, Swap Bank, and press <Enter>. The DMM resets and starts using the

new firmware.

Model 1502 Domain Management Module