Leica Geosystems Leica DISTO D3a BT User Manual

Page 16

Advertising
background image

16

Functions

Leica DISTO™ D3a BT 776750 gb

D

GB

F

I

E

P

NL

DK

S

N

FIN

J

CN

ROK

PL

H

RUS

CZ

defined value (a) is automatically adopted). Value (b)
can be entered using

and

.

The defined value (b) is confirmed with the

button.

Pressing the

button starts the laser measure-

ment. The display shows required stake out distance
in the summary line between the stake out point
(first a and then b) and the instrument (rear refer-
ence).

If the DISTO™ is then moved slowly along the stake
out line the displayed distance decreases. The instru-
ment starts to beep at a distance of 0.1m from the
next stake out point.

The arrows in the display

indicate in which direc-

tion the DISTO™ needs to be moved in order to
achieve the defined distance (either a or b). As soon
as the stake out point is reached the beep changes.

The function can be stopped at any time by pressing
the

button.

Indirect measurement

The instrument can calculate distances using
Pythagoras’ theorem.

)

Make sure you adhere to the prescribed

sequence of measurement:

All target points must be in a horizontal or vertical
plane.

The best results are achieved when the instru-
ment is rotated about a fixed point (e.g. with the
positioning bracket fully folded out and the
instrument placed on a wall).

The minimum/maximum function can be used -
see explanation in "Measuring -> Minimum/
maximum measurement". The minimum value
must be used for measurements at right angles to
the target; the maximum distance for all other
measurements.

)

Make sure that the first measurement and the

distance to be measured are at right angles. Use the
Minimum/maximum function, as explained in
"Measuring -> Minimum/maximum measurement".

a
b
b

Advertising