Measuring conditions – Leica Geosystems Leica DISTO D3a BT User Manual

Page 22

Advertising
background image

22

Appendix

Leica DISTO™ D3a BT 776750 gb

D

GB

F

I

E

P

NL

DK

S

N

FIN

J

CN

ROK

PL

H

RUS

CZ

* maximum deviation occurs under unfavourable conditions such
as bright sunlight or when measuring to poorly reflecting or very
rough surfaces. Measuring accuracy between 10 m and 30 m may
deteriorate to approx. ± 0.025 mm/m, for distances above 30 m
to ± 0.1 mm/m.

Measuring conditions

Measuring range

The range is limited to 100 m.

At night or dusk and if the target is in shadow the
measuring range without target plate is increased.
Use a target plate to increase the measurement
range during daylight or if the target has poor reflec-
tion properties.

Target surfaces

Measuring errors can occur when measuring toward
colourless liquids (e.g. water) or dust free glass,
Styrofoam or similar semi-permeable surfaces.

Aiming at high gloss surfaces may deflect the laser
beam and lead to measurement errors.

Against non-reflective and dark surfaces the
measuring time may increase.

General:
Laser class

II

Laser type

635 nm, < 1 mW

Ø laser point
(at distances)

6 / 30 / 60 mm

(10 / 50 / 100 m)

Autom. laser switch-off

after 3 min

Autom. instrument
switch-off

after 6 min

Display illumination

9

Multifunctional endpiece

9

Timer (self-triggering)

9

Save constant value

9

Historical storage
(20 values)

9

BLUETOOTH® 2.0

9

Range of BLUETOOTH®
Cl. 2

10 m

Tripod thread

9

Battery life,
Type AAA, 2 x 1.5V

up to

5 000 measurements

Protection against
splashes and dust

IP 54, dust-proof,

splash-proof

Dimensions

127 x 49 x 27.3 mm

5 x 1.93 x 1.06 in

Weight (with batteries)

150 g

Temperature range:
Storage

Operation

-25°C up to +70°C

(-13°F up to +158°F)

-10°C up to +50°C

(14°F up to +122°F)