Technical data

245

2nd button pressed
although no Blue-
tooth connection
exists.

Establish Bluetooth
connection

252

Temperature too
high

Cool down instrument

253

Temperature too
low

Warm up instrument

255

Receiver signal too
weak, measurement
time too long,
distance > 100 m

Use target plate

256

Received signal too
strong

Target too reflective
(use target plate)

257

Wrong measure-
ment, background
brightness too high

Darken target (measure
in different lighting
conditions)

260

Laser beam inter-
rupted

Repeat measurement

Error

Cause

Remedy

Error

Hardware error

Switch on/off the
device several times. If
the symbol still
appears, then your
instrument is defective.
Please call your dealer
for assistance.

Cause

Remedy

Distance
measurements:
Measuring accuracy*
up to 10 m
(2 σ, standard deviation)

typically: ± 1/16 in*

(+/- 1.0mm)

Power Range
Technology™:
Range (use target plate
from about 80m)

0.05 m to 100 m

2 in. to 325 ft

Smallest unit displayed

0.1 mm

Distance measurement

9

Minimum/maximum
measurement, Continuous
measurement

9

Area/volume calculation of
room data

9

Addition / subtraction

9

Indirect measurement
using Pythagoras

9

Tilt measurements:
Tilt sensor:
Accuracy
(2 σ, standard deviation)
- to laser beam
- to the housing

± 0.3°
± 0.3°

Horizontal measurement

9

Indirect measurement
using tilt sensor (direct
horizontal distance)

9

Angle measurement using
tilt sensor(± 45°)

9