Functions

Indirect measurement - determining a distance using 2
auxilliary measurements

See figure {P}

e.g. for measuring building heights or widths. It is helpful to use a tripod
when measuring heights that require the measurement of two or three
measurements.

Press this button once, the display shows

. The laser is switched

on.

Aim at the upper point (1) and trigger the measurement

. After

the first measurement the value is adopted. Keep the instrument as hori-
zontal as possible.

Press and hold down this button to trigger continuous measurement

, sweep the laser back and forth and up and down over the ideal target

point.

Press to stop continuous measurement (2). The result is displayed in

the summary line, the partial results in the secondary line.

Press and hold the

key to display additional information about the

measurement of the angles of the triangle

and

.

Indirect Measurement - determining a distance using 3
measurements

See figure {Q}

Press this button twice; the display shows the following symbol

.

The laser is switched on.

Aim at the upper point (1) and trigger the measurement. After the

first measurement the value is adopted. Keep the instrument as horizontal
as possible

Press and hold down this button to trigger continuous measurement

, sweep the laser up and down over the ideal target point.

Press to stop continuous measurement (2). The value is adopted. Aim

at the lower point and

press this button to trigger the measurement (3)

. The result is

displayed in the summary line, the partial results in the secondary lines.

Press and hold the

key to display additional information about for

example the partial distances

,

and the minimum distance

.

Indirect measurement - determining a partial value using
3 measurements

See figure {R}

e.g. determining the height between point 1 and point 2 using three target
points.

Press this button three times ; the display shows the following

symbol

. The laser is switched on.

Aim at the upper point (1).

Press this button and trigger the measurement

. After the first

measurement the value is adopted.

Triggers the measurement

. After the second measurement the

value is adopted.

Press and hold down this button to trigger continuous measurement

. Sweep the laser up and down over the ideal target point.

Press this button to end continuous measurement. The result is

displayed in the summary line, the partial results in the secondary lines.

Press and hold the

key to display additional information about the

measurement of the partial lengths

and

.