Appendix, Storage of constants / historical storage, Historical storage – Leica Geosystems Leica DISTO D5 User Manual

Page 18: Timer (self-triggering), Message codes

Advertising
background image

14

Appendix

Leica DISTO™ D5 LCA782204a en

EN

F

E

P

Storage of constants / historical storage

Storage of a constant

You can store and recall a frequently used value e.g. height of a room.
Measure the desired distance, press and hold the

button until the

device beeps to confirm storage.

Recalling the constant

Press this button once to recall the constant and then press the

button to enter it into your calculation.

Historical storage

Press this button twice and the previous 20 results (measurements

or calculated results) are shown in reverse order.
The

and

buttons can be used for navigation.

Press this button to use a result from the summary line for further

calculations.
Pressing the

and

buttons at the same time erases all the values

in historical storage.

Timer (self-triggering)

Press this button to set a 5-second time delay.

or

Press and hold down this button until the desired time delay is

reached (max. 60 seconds).
Once the key is released with the laser activated, the remaining seconds
until measurement (e.g. 59, 58, 57...) are displayed in a countdown. The last
5 seconds are counted down with a beep. After the last beep the measu-
rement is taken and the value is displayed.

)

The timer can be used for all measurements.

Appendix

Message codes

All message codes are displayed with either

or "Error". The following

errors can be corrected:

Cause

Remedy

156

Transverse tilt greater than 10° Hold the instrument without

any transverse tilt

160

Main tilt direction, angle too

high (> 45°)

Measure angle up to max. ± 45°

162

The calibration has not been

accomplished on a leveled

surface and the calibration value

is respecitvely within an

ineligible area.

Calibrate the device on an abso-

lute horizontal leveled surface.

204

Calculation error

Repeat procedure

252

Temperature too high

Cool down instrument

253

Temperature too low

Warm up instrument

255

Receiver signal too weak,

measurement time too long,

distance > 100 m

Use target plate

256

Received signal too strong

Target too reflective (use target

plate)

257

Wrong measurement,

background brightness too high

Darken target (measure in diffe-

rent lighting conditions)

260

Laser beam interrupted

Repeat measurement

Error

Cause

Remedy

Error Hardware error

Switch on/off the device several

times. If the symbol still appears,

then your instrument is defec-

tive. Please call your dealer for

assistance.