Technical data

* maximum deviation occurs under unfavourable conditions such as bright sunlight or

when measuring to poorly reflecting or very rough surfaces. Measuring accuracy may

deteriorate by approx. ± 0.1 mm/m for distances above 30 m. In long range mode the

maximum deviation from a distance of 30 m increases to +/- 0.15 mm/m.

Distance measurements:

Measuring accuracy up to 30 m

(2 σ, standard deviation)

typically: ± 1.5 mm*

± 1/16 ’’*

Power Range Technology™:

Range (use target plate from about 100 m)

0.05 m to 200 m

Smallest unit displayed

0.1 mm

Distance measurement

9

Minimum/maximum measurement, Conti-

nuous measurement

9

Area/volume calculation of room data

9

Addition / subtraction

9

Indirect measurement using

Pythagoras

9

Trapezium measurement

9

Tilt measurements:

Tilt sensor:

Accuracy (2 σ, standard deviation)

- to laser beam

- to the housing

± 0.3°

± 0.3°

Indirect measurement using tilt sensor

(direct horizontal distance)

9

Angle measurement using tilt sensor(±

45°)

9

General:

Laser class

II

Laser type

635 nm, < 1 mW

Ø laser point

(at distances)

6 / 30 / 60 mm

(10 / 50 / 100 m)

Autom. laser switch-off

after 3 min

Autom. instrument switch-off

after 6 min

Display illumination

9

Multifunctional endpiece

9

Timer (self-triggering)

9

Save constant value

9

Historical storage

20 values

Tripod thread (Type: 1/4-20)

9

Battery life,

Type AA, 2 x 1.5V

up to

5 000 measurements

Protection against splashes and dust

IP 54, dust-proof,

splash-proof

Dimensions

143.5 x 55 x 30 mm

Weight (with batteries)

195 g

Temperature range:

Storage

Operation

-25°C up to +70°C

(-13°F up to +158°F)

-10°C up to +50°C

(14°F up to +122°F)