Appendix, Message codes, Technical data – Leica Geosystems Leica DISTO D8 User Manual
Page 20
EN
F
E
P
17
Leica DISTO™ D8 LCA782206a en
Appendix
Appendix
Message codes
All message codes are displayed with either
or "Error". The following
errors can be corrected:
Technical data
Cause
Remedy
156
Transverse tilt greater than 10° Hold the instrument without
any transverse tilt
162
The calibration has not been
accomplished on a leveled
surface and the calibration value
is respecitvely within an
ineligible area.
Calibrate the device on an abso-
lute horizontal leveled surface.
204
Calculation error
Repeat procedure
240
Data transfer error
Repeat procedure
245
2nd button pressed although no
Bluetooth connection exists.
Establish Bluetooth connection
252
Temperature too high
Cool down instrument
253
Temperature too low
Warm up instrument
255
Receiver signal too weak,
measurement time too long,
distance > 100 m
Use target plate
256
Received signal too strong
Target too reflective (use target
plate)
257
Wrong measurement,
background brightness too high
Darken target (measure in diffe-
rent lighting conditions)
260
Laser beam interrupted
Repeat measurement
Error
Cause
Remedy
Error Hardware error
Switch on/off the device several
times. If the symbol still appears,
then your instrument is defec-
tive. Please call your dealer for
assistance.
Distance measurements:
Measuring accuracy up to 30 m
(2 σ)
typically: ± 1.0 mm*
± 0.04 in*
Power Range Technology™:
Range (use target plate from about 100 m)
0.05 m to 200 m
Smallest unit displayed
0.1 mm
Distance measurement
9
Minimum/maximum measurement, Conti-
nuous measurement
9
Area/volume calculation of room data
9
Addition / subtraction
9
Indirect measurement using
Pythagoras
9
Trapezium measurement
9
Tilt measurements:
Tilt sensor:
Accuracy (2 σ)
- to laser beam
- to the housing
- 0.1° / +0.2° **
± 0.1° **
Indirect measurement using tilt sensor
(direct horizontal distance)
9
Angle measurement using tilt sensor
(360°)
9
General:
Laser class
II
Laser type
635 nm, < 1 mW
Ø laser point
(at distances)
6 / 30 / 60 mm
(10 / 50 / 100 m)
Autom. laser switch-off
after 3 min
Autom. instrument switch-off
after 6 min
Display illumination
9
Multifunctional endpiece
9
Timer (self-triggering)
9