Appendix, Message codes, Technical data – Leica Geosystems Leica DISTO D8 User Manual

Page 20

Advertising
background image

EN

F

E

P

17

Leica DISTO™ D8 LCA782206a en

Appendix

Appendix

Message codes

All message codes are displayed with either

or "Error". The following

errors can be corrected:

Technical data

Cause

Remedy

156

Transverse tilt greater than 10° Hold the instrument without

any transverse tilt

162

The calibration has not been

accomplished on a leveled

surface and the calibration value

is respecitvely within an

ineligible area.

Calibrate the device on an abso-

lute horizontal leveled surface.

204

Calculation error

Repeat procedure

240

Data transfer error

Repeat procedure

245

2nd button pressed although no

Bluetooth connection exists.

Establish Bluetooth connection

252

Temperature too high

Cool down instrument

253

Temperature too low

Warm up instrument

255

Receiver signal too weak,

measurement time too long,

distance > 100 m

Use target plate

256

Received signal too strong

Target too reflective (use target

plate)

257

Wrong measurement,

background brightness too high

Darken target (measure in diffe-

rent lighting conditions)

260

Laser beam interrupted

Repeat measurement

Error

Cause

Remedy

Error Hardware error

Switch on/off the device several

times. If the symbol still appears,

then your instrument is defec-

tive. Please call your dealer for

assistance.

Distance measurements:

Measuring accuracy up to 30 m

(2 σ)

typically: ± 1.0 mm*

± 0.04 in*

Power Range Technology™:

Range (use target plate from about 100 m)

0.05 m to 200 m

Smallest unit displayed

0.1 mm

Distance measurement

9

Minimum/maximum measurement, Conti-

nuous measurement

9

Area/volume calculation of room data

9

Addition / subtraction

9

Indirect measurement using

Pythagoras

9

Trapezium measurement

9

Tilt measurements:

Tilt sensor:

Accuracy (2 σ)

- to laser beam

- to the housing

- 0.1° / +0.2° **

± 0.1° **

Indirect measurement using tilt sensor

(direct horizontal distance)

9

Angle measurement using tilt sensor

(360°)

9

General:

Laser class

II

Laser type

635 nm, < 1 mW

Ø laser point

(at distances)

6 / 30 / 60 mm

(10 / 50 / 100 m)

Autom. laser switch-off

after 3 min

Autom. instrument switch-off

after 6 min

Display illumination

9

Multifunctional endpiece

9

Timer (self-triggering)

9

Advertising