Communication parameters, Menu 53 – Leica Geosystems TPS110C User Manual
Page 53

Menu
53
For data transfer the communi-
cation parameters of the serial
interface RS232 must be set.
Leica Standard setting
19200 Baud, 8 Databit, No
Parity, 1 Stopbit, CR/LF
Baudrate
Data transfer speed 2400, 4800,
9600, 19200
[bits / second]
Databits
7 Data transfer is realized with
7 databits. Is set
automatically if parity is
"Even" or "Odd".
8 Data transfer is realized with
8 databits. Is set
automatically if parity is
"None".
Parity
Even
Even parity
Odd
Odd parity
None
No parity (if data bit
is set to 8)
Endmark
CRLF
Carriage return; line
feed
CR
Carriage return
Stopbits
Fixed setting 1.
RS232 Output
On Measurements made in
Main Measure Dialog with
[DIST] are transfered to
RS232.
Off No data transfer if in Main
Measure Dialog [DIST] was
pressed.
TPS100z97
Communication Parameters
Mask 1/2
Select GSI output mask.
Mask1:
PtID, Hz, V, SD,
pp,+mm, hr, hi
Mask2:
PtID, Hz, V, SD, E,
N, H, hr
Interface plug connections:
1) External battery
2) Not connected / inactive
3) GND
4) Data reception (TH_RXD)
5) Data transfer (TH_TXD)
TH ... Theodolite