Mechanical, Tripod, Circular level – Leica Geosystems TPS110C User Manual
Page 60: Circular level on the tribrach, Checking and adjusting 60

Checking and Adjusting
60
TPS100z44
TPS100z45
1
2
Mechanical
Tripod
The connections between metal
and timber components must
always be firm and tight.
•
Tighten the Allen screws (2)
moderately.
•
Tighten the articulated joints
on the tripod head (1) just
enough to keep the tripod
legs open when you lift it off
the ground.
Circular Level
Level-up the instrument in
advance with the electronic
level. The bubble must be
centered. If it extends beyond
the circle, use the Allen key
supplied to center it by turning
the adjustment screws.
After adjustment no
screw must be loose.
Circular Level on the Tribrach
Level the instrument and then
remove it from the tribrach. If
the bubble is not centred, adjust
it using the adjusting pin.
Turn the adjustment screws:
•
to the left: the bubble
approaches the screw
•
to the right: the bubble goes
away from the screw.
TPS100z43