Coolift – Magliner COOLIFT User Manual

Page 26

Advertising
background image

1-800-MAGLINE (624-5463)

Page 26 www.magliner.com

CooLift

®

Area

Description

Method of Inspection

Normal Condition

Findings Pass or

Fail

Timing

Notes

W

elds

Front caster plate

Visual inspection

No cracks or damage

Monthly

W

elds

Base plate

Visual inspection

No cracks or damage

Monthly

W

elds

Enclosure

Visual inspection

No cracks or damage

Monthly

W

elds

Handle cross bar

Visual inspection

No cracks or damage

Monthly

W

elds

Battery Box

Visual inspection

No cracks or damage

Monthly

W

elds

Vertical slide rod

Visual inspection

•

Rod is straight with no signs of wear

•

Rod plating is not cracked or dam

-

aged

Quarterly

Operator Interface

Guide blocks

•

Visual inspection

•

Cycle deck up and down several times

Blocks are not damaged or worn and move freely in the vertical slide

Quarterly

Operator Interface

Gas spring mounting •

Mounting studs

•

Rod and body connectors

•

Preload screws are tight

Manual / V

isual

inspection

•

Components are tight and connectors engaged fully with studs

Quarterly

Electrical

Wiring •

Wire connections

•

Wire crimps and solder joints

Manual inspection

No loose connections, crimps or solder joints

Quarterly

Electrical

Battery box

Manual / V

isual

inspection

•

Battery box case and cover are free of damage, dents and cracked welds

•

No loose components

•

Cover for charger port is intact

•

Connecting screws to the battery terminals are tight

•

Battery box cover screws are tight

Quarterly

Electrical

Operation

Cycle deck up and down several times

•

Deck should move through entire range of motion without tripping circuit breaker

•

Buttons should not stick in down position

Quarterly