Spec drawing – Cleveland Range IA-MKDL-60-CC User Manual

Page 2

Advertising
background image

SECT.

XIV

PAGE

12

0600

Litho in USA

Cleveland Range reserves right of design improvement or modification, as warranted.

DIMENSIONS

MODEL

A

B

C

D

E

F

ELECTRICAL PER KETTLE -

R.P.M.

208V/ 3PH/60Hz

IA-MKDL-60-CC

32"

52"

64"

45 1/2"

8"

24"

10 AMPS

6-35

IA-MKDL-100-CC

39"

58 1/2"

70"

49 1/2"

9"

28"

12 AMPS

6-35

IA-MKDL-150-CC

45"

63"

79"

52 1/2"

9"

30"

15 AMPS

6-32

IA-MKDL-200-CC

49"

67"

84"

57 1/2"

9"

32"

15 AMPS

6-32

IA-MKDL-300-CC

56"

79"

89"

62 1/2"

11"

36"

25 AMPS

6-32

UTILITY CONNECTIONS

CHILLED

CHILLED

COLD

WATER

WATER

POTABLE

HOT

CONDENSATE

AIR

MODEL

INLET

RETURN

WATER

WATER

RETURN

DRAIN

INLET

STEAM

IA-MKDL-60-CC

3/4"

3/4"

1/2"

1/2"

1/2"

3/4"

1/2"

3/4"

15 GPM

15 GPM

15 GPM

1 CFM

320 lbs/hr

IA-MKDL-100-CC

1"

1"

3/4"

3/4"

3/4"

1"

1/2"

1"

20 GPM

20 GPM

20 GPM

1 CFM

525 lbs/hr

IA-MKDL-150-CC

1 1/4"

1 1/4"

3/4"

3/4"

1"

1 1/4"

1/2"

1 1/4"

20 GPM

20 GPM

20 GPM

1 CFM

780 lbs/hr

IA-MKDL-200-CC

1 1/4"

1 1/4"

3/4"

3/4"

1"

1 1/4"

1/2"

1 1/4"

25 GPM

20 GPM

20 GPM

1 CFM

1050 lbs/hr

IA-MKDL-300-CC

1 1/2"

1 1/2"

3/4"

3/4"

1"

1 1/2"

1/2"

1 1/2"

30 GPM

20 GPM

20 GPM

1 CFM

1575 lbs/hr

** HOT FILL WATER IS OPTIONAL

65 PSI STEAM OPERATING PRESSURE IS RECOMMENDED

**

ELECTRICAL POWER
TO AND FROM
CONTROL PANEL
• CONTRACTOR

MUST CUT ENTRY
HOLE

• TOP OR BOTTOM

POWER ENTRY
RECOMMENDED

• MUST USE PROPER

CONNECTIONS TO
MAINTAIN U.L.
LISTING

OPTIONAL
CONNECTIONS

LOCATED ON SIDE

QUICK DISCONNECT

FOR FOOD PUMP

(LOCATION VARIES)

376

CANCEL

9

8

0

1

2

10

7

5

3

4

6

RESET

SELECT

ENTER

PB

PB

L

AUTO

MAN

376

SELECT

1

2

0

10

9

8

5

7

3

4

6

PB

ENTER

RESET

CANCEL

PB

L

AUTO

MAN

376

1

2

0

8

9

10

PB

3

5

7

4

6

SELECT

ENTER

RESET

CANCEL

PB

L

MAN

AUTO

4"

OPTIONAL HOT

FILL WATER ONLY

69"

69"

24"

40"

E

F

D

C

A

B

REMOVABLE

BAFFLE

PLAN VIEW

FRONT

OPERATIONAL

DEPTH 18 3/4"

CONTROL PANEL

DUAL CONTROL PANEL

IA-DE-CC2

SIDE VIEW

IA-SE-CC2

SINGLE CONTROL PANEL

IF KETTLE IS MORE THAN 3'

FROM THE CONTROL PANEL

THEN THE PRODUCT VALVE

SWITCH WILL BE KETTLE MOUNTED

(LOCATION VARIES)

(NOT TO SCALE)

MINIMUM CLEARANCE

FOR KETTLES

FRONT

36"

SIDE

12"

REAR

12"

Advertising
This manual is related to the following products: