PREVENTIVE

MAINTENANCE

COOK/CHILL MIXER & PASTA KETTLES

A.

AUTOMATIC DUMP VALVE

Weekly
-

Check air collector regulator for moister, dirt, and proper pressure

-

Check all orings and seals and gaskets

-

Check valve operation

-

Lubricate with light oil when needed

-

Check air hose for leaks or signs of wear

B.

TILT MECHANISM ( Hydraulic Tilt )

Weekly
-

Check for leaks

-

Check for smooth operation

-

Check switches

Yearly
-

Change hydraulic fluid every two years. (1 1/2 gallons of
FOOD GRADE hydraulic fluid) ( Shell Telis #5 )

( Electric Tilt )

Weekly
-

Check for smooth operation

-

Check switches

Monthly
-

Check for movement in mechanism

-

Grease trunnions monthly ( Food Grade Grease )

C.

AIR PRESSURE

Weekly
-

45 psi dump valve - 15 psi for jacket purge

-

Air must be clean and dry

-

Check all air lines & fittings for leaks

D.

STEAM TRAP

Monthly
-

Check proper operation