PREVENTIVE

MAINTENANCE

COOK/CHILL MIXER & PASTA KETTLES (continued)

E.

SAFETY VALVE

Weekly
-

Check for leakage

-

Steam pressure 65 psi. max.

-

Safety set at 100 psi.

F.

LEAKS

Weekly
-

Check for leaks of any type ( water - steam - hydraulic )

( Leaks take away from performance and will lead to costly repair )

G.

Control Panels

Weekly
-

Signs of water damage

-

Check operation of all controls

-

Water meter operation

-

Temp read outs

-

Temp charting

-

Temp controlling

-

RTD adjustments

-

Mixer operation & speed control

-

Gentle heat operation

-

product valve operation