Carrier AQUAZONE 50PCH User Manual

Page 13

Advertising
background image

13

NO

T

E

S:

1.

Compre

ssor

ther

ma

lly p

rot

ecte

d i

nte

rnal

ly

.

2.

All wir

ing to

t

he unit

m

u

st comply with

NE

C

an

d

lo

cal co

des

.

3.

T

ransf

or

m

er is wired t

o 460-

v B

LK/

RED lead f

o

r 460-3

-60 un

its or 57

5-v

GR

Y le

ad f

or

575-

3-60

unit

s

. T

ran

sf

or

mer

is e

nerg

y

l

imiti

ng or

ma

y ha

v

e

ci

rcuit

br

eak

er

.

4.

FP1 t

her

mistor

pro

v

ide

s

lo

w te

mper

a

tur

e pr

ote

c

ti

on

f

or

w

at

er

. Whe

n

using ant

if

reez

e solut

ions

,

cut

JW3 jump

er

.

5.

Ref

e

r t

o

micropr

ocesso

r

con

tr

o

l,

L

O

N, or

t

her

mosta

t inst

allat

ion

i

n

str

u

c-

tio

n

s

fo

r wir

in

g to t

he un

it.

Wire “Y

” fro

m

ther

mosta

t t

o

Y

1” Delu

x

e

D

when mo

to

ri

z

ed v

alv

e is n

ot

used.

Ther

mo

st

at

wir

ing m

u

st

be

Class

1

and v

olt

age r

at

ing

equ

al to or g

re

ate

r

than

un

it supply v

o

lta

ge

. Heat

/coo

l

th

er

most

at

s not

co

mpat

ib

le

wit

h mot

or

iz

ed

w

at

er v

a

lv

e

.

6.

24-

v a

lar

m sig

nal sho

w

n.

F

o

r dr

y ala

rm cont

act,

cut

JW4 ju

mper a

nd dr

y

cont

act will be a

v

ai

lab

le

b

et

w

een AL

1

a

nd AL2.

7.

T

ransf

o

rmer

secondar

y g

rou

nd via

g

reen

wire

wit

h y

e

llo

w st

ri

pe

f

rom

“C”

te

rmina

l

to

cont

rol bo

x.

8.

Blo

w

e

r mot

o

r is f

a

cto

ry wire

d

f

o

r me

dium an

d high

spe

eds

. F

o

r an

y

ot

her

co

mbinat

ion

of

spee

ds

, a

tt

ach b

lac

k wi

re t

o t

he

high

er o

f

the

t

w

o

desire

d spee

d t

aps at

t

he mo

tor

. A

tt

ach t

he

b

lue

wire

to

th

e lo

w

er

of

th

e

tw

o

d

esired

spee

d t

aps

.

9.

Blo

w

e

r

mot

o

r is

fa

ct

or

y w

ired f

o

r

h

igh and lo

w

speed

s

.

No oth

e

r

comb

i-

nat

ion

of

sp

eeds is

a

v

a

ilab

le

.

10.

The 460

-v unit

s

u

s

ing an i

n

te

rnal

secon

dar

y pump will r

equir

e

a neu

tr

al

wire f

rom the

sup

ply

side

in

o

rder t

o f

eed t

he acce

ssor

y w

ith 265

-v

.

a50-8

492

Fig. 15 —

50PCH

,PCV

Units with Delu

xe

D Cont

ro

ller, Thre

e

-P

has

e

(4

60 V)

D

elux

e D

LEG

E

ND

Rela

y/Co

nta

c

tor Coil

Cond

ensat

e P

a

n

So

lenoi

d Co

il

Ther

mist

or

Gr

ound

Wire

Nut

*O

p

tio

nal.

AL

A

lar

m Rela

y

Con

tacts

BM

Blo

w

e

r M

o

to

r

BMC

B

lo

w

er Mot

o

r Capacit

or

BR

B

lo

w

er Rela

y

CB

Circui

t Bre

a

k

e

r

CC

Comp

ressor C

o

nt

actor

CO

S

ensor

, Con

densat

e

Ov

erf

lo

w

FP1

S

ensor

,

Lo

w T

emper

at

ure Pr

ote

c

ti

on

W

at

er Coil

FP2

S

ensor

,

Lo

w T

emper

at

ure Pr

ote

c

ti

on

A

ir C

o

il

HP

High

-Pre

s

sur

e

Switch

HPWS

High

-Pre

s

sur

e

W

a

ter

Switch

JW1

Clip

pab

le F

ield Sel

e

ctio

n

J

u

mper

LO

C

Lo

ss of

Cha

rge Pre

s

sur

e

S

witch

MV

Mot

o

ri

z

e

d V

a

lv

e

MVES

Mot

o

ri

z

e

d V

a

lv

e

End

Swi

tch

NEC

Nat

iona

l E

lect

rical

Code

P1

Field

Wi

ri

ng

T

e

rminal

Blo

c

k

PB

Po

w

e

r B

lo

c

k

RV

S

Re

v

e

rsing V

a

lv

e

S

o

leno

id

TRAN

S

T

ransf

or

mer

TXV

Ther

mosta

tic Expansio

n

V

a

lv

e

Field

L

ine V

o

lta

ge Wir

ing

Field

L

o

w

V

o

lt

age Wir

ing

Pr

inted Circuit T

race

Op

tio

nal Wir

ing

Advertising