Chapter 3 - Parameter List

33

Code

Description

Keypad

Display

Setting Range

Units

Factory

Default

Adj.

During

Run

Page

2 (Stop)

I/O-49

Waiting Time after Loss of Freq.
Reference

I 49

0.1 to 120.0 [sec]

0.1

1.0 [sec]

Yes

0 (CMC- Bus ASCII)

I/O-50 Communication Protocol Selection

I 50

7 (Modbus-RTU)

-

7 (Modbus-

RTU)

Yes 73

I/O-99 Return Code

rt

-

1

Yes

73


Note:
Parameters that are set by a bit are ON (1) when the upper LED is lit as shown below.
(F59, H19, H22, I15, I16, I45 are the parameters that are set by bit.)

Example) when the keypad displays ‘00000011’









Note: FU1-20, FU1-21, FU1-25, FU1-36, FU2-54, FU2-83, I/O-05 and I/O-10 are set at 50Hz for Standard (EU)
types and 60Hz for US types. Please check these parameters before commissioning to veryfiy that you have
the right product.