EN

GL

ISH

WWW.STIEBEL-ELTRON.COM

DHC |

5

INSTALLATION

ELECTRICAL CONNECTION

6. Tankless water heaters such as the DHC are not required to

be equipped with a Pressure and Temperature Relief Valve

(PTRV). If the local inspector will not pass the installation

without a PTRV, it should be installed on the hot water outlet

side of unit.

7. In case you are connecting to 1/2“ water pipe, solder 1/2“

NPT tapered female adapter by copper on ends of cold and

hot water lines. In case you are connecting to 3/8“ water

pipe, use a 1/2“ female pipe thread by 3/8“ compression

adapter. Braided flexible connectors will work as well. Con-

nect cold and hot water lines to the unit.

8. When all plumbing work is completed, check for leaks and

take corrective action before proceeding.

6. Electrical connection

DANGER Electrocution

BEFORE BEGINNING ANY WORK ON THE ELECTRIC IN-

STALLATION, BE SURE THAT MAIN BREAKER PANEL

SWITCH IS „OFF“ TO AVOID ANY DANGER OF ELEC-

TRIC SHOCK. ALL MOUNTING AND PLUMBING MUST

BE COMPLETED BEFORE PROCEEDING WITH ELECTRI-

CAL HOOK-UP. WHERE REQUIRED BY LOCAL, STATE OR

NATIONAL ELECTRICAL CODES THE CIRCUIT SHOULD BE

EQUIPPED WITH A „GROUND FAULT INTERRUPTER“.

1. All electrical work must comply with national and applicable

state and local electrical codes.

2. The DHC should be connected to a properly grounded dedi-

cated branch circuit of proper voltage rating. In installa tions

with several DHC units, each unit requires an independent

circuit. Please refer to the technical data table for the correct

wire and circuit breaker size.

3. The wire must be fed through the rubber seal located be-

tween the hot and cold water connections. Then feed wires

through strain relief clamp and tighten clamp down on wire.

The „live“ wires must be connected to the slots on the ter-

minal block marked N and L (DHC 3-1 only) or L and L (all

other versions). The ground wire must be connected to slot

marked with the ground symbol.

4. Reinstall plastic cover.

26

�0

2�

02

�0

46

9

DANGER Electrocution

AS WITH ANY ELECTRIC APPLIANCE, FAILURE TO ELEC-

TRICALLY GROUND UNIT MAY RESULT IN SERIOUS INJURY

OR DEATH.

7. Putting the water heater into

operation

!

WARNING

OPEN HOT WATER FAUCET FOR A FEW MINUTES UNTIL

WATER FLOW IS CONTINUOUS AND ALL AIR IS PURGED

FROM WATER PIPES. THE UNIT’S PLASTIC COVER MUST

BE INSTALLED BEFORE THE CIRCUIT BREAKER IS TURNED

ON.

1. Turn on circuit breaker to bring electrical power to the unit.

2. Open hot water faucet to a degree so that water flow is „typi-

cal“ i.e. until the water flow is the same as that encountered

during normal use.

3. Wait twenty seconds until temperature has stabilized. Then

check water temperature. If temperature is too low, the

water flow rate needs to be reduced. In order to do this,

turn off the unit’s circuit breaker, remove the cover and turn

the flow adjustment screw shown in illustration clockwise

1/2 turn (180 degrees). Then reinstall plastic cover, turn

on circuit breaker and check water temperature. This pro-

cedure should be repeated until the desired temperature is

achieved. In case the water temperature is too high, turn the

flow adjustment screw counter clockwise in the same man-

ner until the desired temperature is achieved. The arrows in

illustration refer to the water temperature.

4. In order to obtain temperature control at a single spout mix-

er-type faucet, restrict cold water flow to faucet by partially

closing the cold water shut-off valve under the sink until cold

water and hot water flow rates are approximately the same.

8. Normal maintenance

STIEBEL ELTRON DHC tankless heaters are designed for a very long

service life. Actual life expectancy will vary with water quality and

use. The unit itself does not require any regular maintenance.

However, to ensure consistent water flow, it is recommended

to periodically remove scale and dirt that may build up at the

aerator of the faucet or in the shower head. Also, the DHC has

a built in filter screen that should be cleaned from time to time.

In order to do this, turn off the cold water supply at the isolating

valve and remove the ground wire. Twist cold water supply tube

counterclock wise by 90° and pull towards bottom of unit. Clean

screen and put the screen, the cold water supply tube and the

ground wire back into their original position. Please be sure that

the ground wire is reinstalled and that ground screw is securely

tightened after this procedure.

Note

OTHER THAN THE FILTER SCREEN, THE DHC DOES NOT

CONTAIN ANY PARTS SERVICEABLE BY THE LAY PERSON.

IN CASE OF MALFUNCTION PLEASE CONTACT A LICENSED

PLUMBER OR ELECTRICIAN.