| SHC 2.5 / SHC 4

www.stiebel-eltron-usa.com

INSTALLATION

General Recommendations

7. General Recommendations

The installation must be carried out by licensed profes-

sionals. All state and local codes must be adhered to.
The manufacturer will not be liable for any damages be-

cause of failure to comply with these installation instruc-

tions or because of improper installation performed by

an unqualified installer.

NOTE:

Choose a location that allows easy access for

maintenance or servicing.

The water heater should be installed with at

least 8˝ of clearance on the top and sides of

the unit.

8. Mounting the Unit

!

NOTICE:

UNIT MUST BE INSTALLED IN A VERTICAL PO-

SITION WITH THE WATER FITTINGS POINTING

UPWARD.

WARNING:

DO NOT INSTALL UNIT WHERE IT WOULD ROU-

TINELY BE SPLASHED WITH WATER. ELECTRIC

SHOCK MAY RESULT.

CAUTION:

HOT WATER OUTLET PIPES LEAVING UNIT CAN

BE HOT TO THE TOUCH. INSULATION MUST BE

USED FOR HOT WATER PIPES BELOW A HEIGHT

OF 36˝ DUE TO BURN RISK TO CHILDREN.

!

NOTICE:

THIS UNIT SHOULD NOT BE INSTALLED IN A

LOCATION WHERE IT MAY BE EXPOSED TO

FREEZING TEMPERATURES (LESS THAN 36 °F

[2 °C]). IF THE UNIT MAY BE SUBJECT TO FREEZ-

ING TEMPERATURES, ALL WATER MUST BE

DRAINED FROM THE UNIT. FAILURE TO COMPLY

WITH THIS INSTRUCTION VOIDS ALL WARRAN-

TIES.

THE UNIT SHOULD BE LOCATED IN AN AREA

WHERE WATER LEAKAGE FROM THE UNIT OR

CONNECTIONS WILL NOT RESULT IN DAMAGE

TO THE AREA ADJACENT TO THE UNIT. IF SUCH

A LOCATION CANNOT BE AVOIDED IT IS REC-

OMMENDED THAT A DRAIN PAN BE INSTALLED

UNDER THE UNIT.

1. Drill two (2) 1/4 inch holes in the wall where the

water heater will be mounted.

2. Install plastic wall anchors.

3. Fasten wall mounting bracket to the wall.

4. Hook water heater to the mounting bracket.

5. Pull downwards on the water heater to properly

seat it on the bracket.

9. Plumbing Connections

!

IMPORTANT:

IF WATER PIPES ARE OF COPPER OR BRONZE,

USE DIELECTRIC CONNECTIONS TO PREVENT

HEATER CORROSION. FAILURE TO PROVIDE

DIELECTRIC INSULATION MAY RESULT IN PRE-

MATURE TANK OR NIPPLE FAILURE AND MAY

VOID YOUR WARRANTY.

!

NOTICE:

HARD WATER OR WATER WITH A HIGH MINER-

AL COUNT MAY DAMAGE THE UNIT. DAMAGE

TO THE UNIT CAUSED BY SCALE OR A HIGH

MINERAL COUNT IS NOT COVERED UNDER THE

WARRANTY.

CAUTION:

TO REDUCE THE RISK OF EXCESSIVE TEMPERA-

TURE AND PRESSURE IN THE WATER HEATER,

A COMBINATION TEMPERATURE/PRESSURE

(T&P) RELIEF VALVE IS SUPPLIED WITH THE

WATER HEATER AND MUST BE INSTALLED.

CAUTION:

ALWAYS FILL THE UNIT’S TANK WITH WATER

BEFORE PLUGGING THE WATER HEATER’S CORD

INTO AN ELECTRICAL OUTLET. FAILURE TO DO

SO WILL RESULT IN PERMANENT DAMAGE TO

THE WATER HEATER.

!

NOTICE:

WHEN A WATER HEATER IS INSTALLED IN A

CLOSED WATER-SUPPLY SYSTEM, SUCH AS

ONE HAVING A BACK-FLOW PREVENTER IN

THE COLD- WATER SUPPLY, MEANS SHALL BE

PROVIDED TO CONTROL THERMAL EXPANSION.

CONTACT THE WATER SUPPLIER OR LOCAL

PLUMBING INSPECTOR FOR INFORMATION

REGARDING THE CONTROL OF THIS SITUATION.

Connect the cold water pipe to the cold water connection

on the unit (blue). Connect the hot water pipe to the hot

water connection on the unit (red).