Installation spare parts, Spare parts, What to do if – STIEBEL ELTRON SunWarmth CIR 400-2 O User Manual

Page 21: 4 specification table, Cir infrared heater| 21 en g l is h, The appliance does not heat up

Advertising
background image

WWW.STIEBEL-ELTRON-USA.COM SUNWARMTH

CIR INFRARED HEATER|

21

EN

G

L

IS

H

INSTALLATION

SPARE PARTS

11.4 Specification table

Model

CIR 150-1 I

CIR 150-1 O

CIR 200-2 O

CIR 400-2 O

Item No.

234047

234048

234049

234050

Usage

indoor only

indoor/outdoor

indoor/outdoor

indoor/outdoor

Testing standard

ANSI/UL 1278

ANSI/UL 1278

ANSI/UL 2021

ANSI/UL 2021

Voltage, 60Hz

115–120 V

115–120 V

230–240 V

230–240 V

Wattage

1.5 kW

1.5 kW

2.0 kW

4.0 kW

Amperage

12.5 A

12.5 A

8.3 A

2 x 8.3 A

Required number and size of

circuit breakers

N/A

N/A

15 A

2 x 15 A

Required wire size

(copper)

14 AWG

14 AWG

12 AWG

12 AWG

Lamp temperature

2420 °F, ±360 °F

1325 °C, ±200 °C

2420 °F, ±360 °F

1325 °C, ±200 °C

2420 °F, ±360 °F

1325 °C, ±200 °C

2420 °F, ±360 °F

1325 °C, ±200 °C

Lamp life

(normal conditions)

5000 hours

5000 hours

5000 hours

5000 hours

Lamp color temperature

1600 K, ±200 K

1600 K, ±200 K

1600 K, ±200 K

1600 K, ±200 K

Height

5

11

/

16

˝ / 145 mm

5

11

/

16

˝ / 145 mm

5

11

/

16

˝ / 145 mm

5

11

/

16

˝ / 145 mm

Width

15

9

/

16

˝ / 395 mm

18

9

/

16

˝ / 471 mm

18

9

/

16

˝ / 471 mm

38 ½˝ / 978 mm

Depth

4

7

/

16

˝ / 112 mm

4 ¼˝ / 108 mm

4 ¼˝ / 108 mm

4

7

/

16

˝ / 112 mm

Weight

4.85 lb / 2.2 kg

5.5 lb / 2.5 kg

5.5 lb / 2.5 kg

8.8 lb / 4.0 kg

IP-Rating

IP20

IP24

IP24

IP24

Protection class

I

I

I

I

Color

alpine white

alpine white

alpine white

alpine white

12. Spare Parts

Model

Protective grill

Heat Lamp

CIR 150-1 I

BHSG

LGHS1520 120V

CIR 150-1 O

BHSG

LGHS1524 120V

CIR 200-2 O

BHSG

LGHS2024 240V

CIR 400-2 O

BHSG

(2) LGHS2024 240V

13. What to do if ...

... the appliance does not heat up:

»

For 120 V models, ensure that the unit is plugged into a properly

grounded 120 V wall outlet and that the timer switch is on.

»

For 240 V models, ensure that the timer switch is on and that

there is adequate power available at the circuit breaker and that

the breaker hasn’t tripped. Check for faulty breaker(s).

... you notice a smell:

»

For a short time after initial installation or after a long period

of inactivity, the unit may produce a smell. This is normal and

will not last long once regular operation resumes.

If you cannot remedy the fault, contact your contractor. To facilitate

and speed up your enquiry, please provide the number on the type

plate (Nr. XXXXXX - XXXX - XXXXXX)

Advertising