Reventative, Aintenance, Chedule c – Conair SC-5 User Manual

Page 71

Advertising
background image

●

Weekly

❒

❒ Cleaning the blade lubrication tray (if the cutter
has this

option).

See Cleaning the Blade Tray,

Section 5.
❒

❒ Lubricating shafts on optional slide rail system

See Cleaning the Blade Tray, Section 5.

●

Monthly

❒

❒ Checking hardware on the knife guard

Inspect the hardware on the knife guard (fasteners on
hinge and the clear blade guard window). Tighten as
needed.

❒

❒ Checking bushing holder proximity switches

Inspect the sets screws which retain the bushing holder
proximity switches for tightness. Adjust as needed. See
Adjusting the Proximity Switches, Section 5.

❒

❒ Checking the draw latch

Inspect the latch on knife guard windows for wear and

P

REVENTATIVE

M

AINTENANCE

S

CHEDULE

C

ONTINUED

UGE059/1003

SC-5 SURE CUT Servo Knife Cutter

M

AINTENANCE

5-5

❒

❒ Clean the clear blade guard window

Clean using glass cleaner or plain water. Other materi-
als may cause premature loss of clarity or crazing.

●

Semi-annual (every 6 months)

❒

❒ Inspecting electrical terminals

Check all electrical terminals for tightness; adjust as
needed. See Checking Electrical Connections, Section
5.

❒

❒ Checking torque on Trantorque coupling device

Check the tightness (torque) of the Trantorque coupling
device with a torque gauge. This device connects the
cutter head to the Micron reducer shaft. See Checking
Torque, Section 5.

❒

❒ Checking all electrical cables

Inspect all electrical cables for cuts and abrasions.
Replace as needed.

❒

❒ Inspecting control panel lights

Check to make sure no LEDs or lights are burned out
on the control panel. Replace as needed.

Draw Latch

Clear Guard Windows

Advertising