5 .0 I N STALLI N G BAT T ERI ES

1. Turn the gauge over and locate the battery

compartment. You do not have to remove
the rubber shell.

2. Open the battery compartment by pulling

down on the tab located at the top of the
battery cover and remove the cover.
Insert two AA batteries following the
orientation engraved on the inside of the
battery compartment.

3. Replace the battery cover by inserting the

two tabs located on the bottom edge of the
cover into the matching slots in the housing.

4. Push the cover closed until the tab at the

top of the battery cover “clicks” into a
locked position.

5. Replace the cut-out section of the protective

rubber shell.

click

11

9 .0 M EASU RI N G RPM

9.1 Contact Operation - RPM

1. Install the Slide-on Contact Adapter.

Push on securely

2. Slide the Cone Tip adapter over the shaft of

the instrument. Be sure to align the pin on
the side of the shaft with the slot in the
adapter. Push on securely.

3. Select the Contact RPM mode by pressing

the MODE key until the rpm symbol appears
in the top left corner of the LCD display

4. Position the adapter carefully so that it contacts the center of

the rotating shaft. Apply enough pressure to eliminate any slip.

5. Press and hold the MEASURE key to take measurements.

6. Release the MEASURE key prior to removing the instrument from

the rotating element. The LAST reading will be retained on the
display.

MO

D

E

M

EM

ma

x

m

in

mem

rp

m

m

/min

ft/m

in

in

/m

in

8.8.8.8

.8

SLOT

PIN