Checkline ETMPX User Manual

Page 12

Advertising
background image

– 12 –

The MEM Mem indicator is frozen on the DISPLAY and the
current reading is displayed. The tension meter has changed back to
measuring mode.

To Save The Next Measuring Period:

1. Press the MEM key again. The DISPLAY shows the memory

mode “C” and the next memory number.

6.4 Data Logging in Mode L (Limit)

1. Turn on the tension meter.
2. Memory Mode C set as described in Sec. 6.1
3. Insert process material and begin measuring as described in Sec. 4.0.

To Start Data Logging:

1. Press and hold the MEM key until the DISPLAY shows the

memory mode “L” and the current memory number.

2. Release the MEM key. The tension meter starts logging the data.

While the tension data are stored, the MEM indicator blinks on the
DISPLAY and the currently measured value is displayed.

To Stop Data Logging:

1. To stop data logging, press the MEM key once again. The statistical values are

calculated and stored in the following order:

Average value

Last value

Maximum value (MAX)

Minimum value (MIN)

Minimum peak value (MIN PEAK)

Maximum peak value (MAX PEAK)

Tension Value

- 1 -

Tension Value

- 2 -


Tension Value

- 10 - (up to 10 tension values in up to 255 measuring periods.)

The MEM indicator is frozen on the DISPLAY and the current
reading is displayed. The tension meter has changed back to
measuring mode.

3

Mem cN

3

Mem cN

3

Mem cN

C 2

Mem cN

L 1

cN

– 25 –

Procedure

1. Remove the FILAMENT GUIDE by loosening

the SETSCREWS (2) using the

supplied screwdriver (1.5m blade width).

2. Slide the FILAMENT GUIDE down the

ROLLER SHAFTS in the direction of the
arrow.

12.0 APPENDIX B - REPLACING THE ROLLERS/CERAMIC PINS

You should regularly inspect the rollers to assure that they are running easily and
smoothly. You can replace the rollers yourself, as necessary, by following the directions
in this section. Please indicate the tension meter model and the serial number (given on
the rear side of the tension meter) in your spare-parts order.

Model: 03/04
ETMX-100
# 400 - 88888

Model ID

Serial number

NOTE: Replacing rollers with
ceramic pins or ceramic pins with
rollers can only be performed at
the manufacturer’s facility.

GUIDE ROLLERS (2x)

ROLLER SHAFTS (2x)

FILAMENT GUIDE

GRUB SCREWS (2x)

MEASURING ROLLER