1. Loosen the hose clamp securing the return
hose to the control valve return elbow using a
5/16" socket or a flat-blade screw driver. See
Figure 6-121.
2. Remove, drain, cap and position the return
hose out of the work area.
3. Remove, drain, cap and position the high pres-
sure hydraulic hose out of the work area using
channel locks and a 1-1/16" wrench. See Fig-
ure 6-122.
4.
Remove the steel hydraulic tube that connects
from the rear port of the hydraulic cylinder to
the 90 degree fitting on the control valve using
two 7/8" wrenches. See Figures 6-123 and 6-
124.