Hardy HI 2151/30WC Single-Scale Controller User Manual

Page 113

Advertising
background image

Chapter 7 - Operation

7-15

Dip Switch #1 (S3)

Position Bit

Function ("ON" position)

1

80

Multi-drop

2

01

Calibrate toggle (Non NBS applications)

3

40

Serial command lockout (Requests OK)

4

02

Option menu lockout

5

04

Set point menu lockout

6

20

Spare

7

08

Lb/Kg, N/G, Tare and Zero lockout

8

10

Zero track

SUB-CMD

Meaning

Dip Switch #2 (S2)

Position Bit

Function ("ON" position)

1

08

Ignore incoming checksums

2

10

On is averaged peak hold, Off is instantaneous

peak

hold

3

20

NBS

4

04

NBS Re-Cal toggle switch

5

40

Spare

6

80

Spare

7

02

Spare

8

01

Spare

SUB-CMD

Meaning

E

Excitation Monitor
ERR
OKK
OFF

3. E IT

®

serial command

Results

Description

OKK

No Errors Detected

ERR

Error Detected

OFF

IT is Not Turned On

4. I

Load cell input command. Used primarily to
check the analog input section of the unit. The command
will return the number of averaged counts that is currently
being read from the load cell input.