Chapter 8 - Troubleshooting

8-9

A - Guidelines for
Instabilities on
Formerly Operating
Systems

Press TST/CLR: To START INTEGRATED TECHNICIAN

( I.T.) diagnostic program

Select System Check: SYS_TST Press: ENTER

This program level
isolates the instrument
from the rest of the
weigh system and
checks the internal
electronics stability

Monitor the display for

stability

STABLE ?

Press ENTER

to continue testing

This next step isolates
the controller and
loadpoint signal cable
from the weight
vessel. Tests the
controller and loadcell
signal cable to the I.T.
JUNCTION BOX.

STABLE ?

Yes

Cont.

C

A

STABLE ?

Monitor the

Display for stability

A1

Verify tight cable connections and

cable integrity.

Replace

Integrated Technician

Summing card

NO

YES

NO

B1

NO

STABLE ?

NO

YES

YES

Advertising